EMI 차폐 / 전자파 차폐

Electro Magnetic Interference (EMI) Shielding

  • Conductive Transparent Glass for TFT Displays
  • For military, medical, marine, avionics, test and measurement
  • Film and glass
Sensitive medical, military or aerospace applications are subject to strict regulations concerning electromagnetic interference. In order to meet these requirements with our TFT displays and to shield the interference of the TFT cell, we use conductive transparent EMI mesh foil laminated to glass or plastic substrates such as acrylic, polycarbonate or polyester (PET) etc. The silver-coated gasket, busbar are used for grounding via the TFT display bezel.
Applications
  • Military displays
  • Medical equipment and MRI rooms
  • Marine
  • Avionics
  • In-flight entertainment displays
  • Secure TEMPEST equipment
  • Test and measurement
Fitting options
  • Optical Bonding
  • Cover window : PMMA, PC, Glass and etc…
  • Extra contact edge options
    – EMI Gasket : Silver busbar, Copper edges for grounding
SPECIFICATION MODEL TEST METHOD
EMT100 EMT150 EMT185
Available size Upon Customer’s request
Cover Window Clear or AG glass on standard, Various version
EMI electromagnetic shielding film OCA 20±5μm ASTM D374
Conductive layer 100±5μm
Protective Film 50~60μm
Mesh type & angle Square 45 degree
Line width 17μm 17μm 21μm
Line distance 238μm 143μm 255μm
VLT ≥80% ≥75% ≥81% GB/T 2410-2008
Surface resistance (conductive side) ≤0.2Ω/□ ≤0.2Ω/□ ≤0.1Ω/□ 4 probe tester
Adhesion strength (conductive side) Min. grade 2 GB/T 9286-1998
Moisture & heat Test Resistance change ≤30% 65℃ , 90%, 100hr
VLT change ≤5%
EMI SHIELDING PERFORMANCE
Item VLT Frequency / shielding dB
14K 100K 10M 30M 150M 450M 950M 1G 3G 6G 10G
EMT100 (100OPI) >80% 8 9 32 41 66 51 47 47 35 31 26
EMT150 (150OPI) >75% 11 13 38 49 76 63 55 53 44 40 35
EMT85 (85OPI) >81% 8 9 30 40 63 50 45 45 35 30 25
* The specification is subject to change without prior notice.